top of page

LEFOO pressure switches and transmitters for industrial projects

49 minutes ago
2 min read

Start with the decision the measurement must support. A filter alarm needs a change of state. A building management system that trends room pressure needs a measured value. A process line also needs a pressure connection and wetted materials suited to the medium. These choices lead to different instruments in the LEFOO range.

Room pressure and HVAC filters

For a room with a maintained pressure difference, identify the reference space, the direction of the pressure difference and where staff need to see an alarm. The embedded differential pressure transmitter has a local display and alarm. Check its selected range and output against the receiving controller. The LFM55 manufacturer datasheet gives the model reference for the cleanroom application guide.

If maintenance needs a filter alarm at a set pressure difference, compare the adjustable air differential pressure switch. Specify the required trip point, reset behaviour and controller input. The LF32 commissioning guide and manufacturer reference cover this switch application.

Pump, compressor and process pressure

For a pump skid that needs both a measured signal and switching outputs, review the digital pressure switch with 4–20 mA and dual switch control. Record the process range, operating setpoints, connection and receiving inputs. The pump pressure control guide explains the wider controls application. For compressor cycling, use the pressure switch selection guide to scope the switching duty.

For a hygienic process connection, compare the sanitary clamp pressure transmitter. Confirm the mating clamp dimensions, seal, wetted materials and cleaning conditions for the installation. For tanks requiring both liquid level and temperature, review the dual-output liquid level and temperature transmitter and identify the input needed for each reading.

Monitoring and project quotation

List the instrument, receiving input and alarm destination for each measuring point. A typical project takes a switch contact or transmitter output into a suitable BMS or PLC input. Trending and remote alarms depend on the selected controller, gateway and software. Include these separately when requesting the system price.

Request a LEFOO instrument or system quotation. Include the site, medium, range, connection, power, signal and quantity. The product pages above show pricing and options for the listed instruments. A configured project quotation can also cover interfaces, integration and commissioning.

bottom of page