Supplier-reported project; customer unnamed. Mexico.


Project attribution: the work described below is reported by JUJEA and its project partners. ProSense is providing application commentary and does not claim to have delivered this installation.


The documented project


JUJEA reports a Mexican water-conservancy application involving a DN300 clamp-on ultrasonic flow meter. The account describes full-pipe water flow and temperature monitoring and highlights installation adjustments as part of resolving the earlier measurement problem.



Original ProSense planning graphic for Clamp-on water metering: Pipe survey, Mounting location, Signal quality, Comparison record

Original ProSense planning graphic; not a photograph of the supplier installation.


Applying the idea to a new project


For an existing water main, start by confirming what the survey or permanent measurement must answer. A commissioning comparison, pump performance investigation and ongoing water balance need different recording periods and acceptance criteria. Decide whether a portable survey should precede permanent equipment selection.


Equipment and integration questions


Provide actual pipe outside diameter, wall thickness, material, lining and fluid conditions. Mark nearby pumps, elbows, valves and available straight pipe on a sketch. Confirm transducer mounting access and the manufacturer's requirements for the proposed pipe before assuming a clamp-on installation will work.


What to verify before handover


Keep a record of transducer spacing, pipe parameters, signal quality and the conditions during verification. Compare like-for-like time periods and units when reconciling the new reading with another meter. Investigate a discrepancy before using it as evidence of a water loss.


Source and evidence


Source reviewed 2 November 2026. This summary relies on the linked publisher's account; ProSense has not independently audited the installation or its outcomes. Supplier performance figures and approvals do not automatically apply to another project. Commentary prepared with AI assistance.