Sensor & Measurement
-
Sensor Type: PT100 platinum RTD
-
Measurement Principle: Resistance temperature detection (RTD)
-
Measurement Range: Up to 120 °C and above (model and installation dependent)
-
Measurement Type: Temperature
Measurement Disclaimer:
Specified temperature range applies to the sensing element only. Actual allowable operating temperature depends on probe construction, installation method, and environmental conditions. Continuous operation near maximum limits may reduce service life.
Electrical Specifications
-
Nominal Resistance: 100 Ω at 0 °C (PT100 standard)
-
Output Type: Passive resistive signal
-
Power Requirement: External excitation from connected instrument
-
Battery Included: No
Electrical Disclaimer:
Measurement accuracy depends on correct excitation current, wiring method (2-wire, 3-wire, or 4-wire), and compatibility with the connected instrument. Incorrect wiring may introduce measurement error.
Mechanical Specifications
-
Probe Type: Standing probe
-
Construction: Waterproof probe body
-
Cable Length: 1 m (fixed)
-
Electronics: None (passive sensor)
Mechanical Disclaimer:
Mechanical durability and ingress resistance depend on correct installation, strain relief, and environmental exposure. Excessive bending or tensile stress on the cable may cause sensor failure.
Environmental & Protection
Environmental Disclaimer:
Waterproof performance applies to the probe only and does not extend to cable terminations or connection points unless additional sealing is provided.
Compliance & Safety
-
Certification: CE marked (manufacturer declaration)
-
Hazardous Substances: No high-concern chemicals declared
-
Country of Origin: Mainland China
-
Intended Use: Industrial temperature measurement and control
Compliance Disclaimer:
CE marking applies to the sensor as a component only. Final system compliance—including electrical safety, EMC, and installation standards—is the responsibility of the system designer or installer. ProSense does not certify complete systems or site installations.
Installation & Use Limitations
-
Passive sensing element only (no signal conditioning)
-
Not a safety-rated device
-
Not suitable as a primary over-temperature protection device
-
Installation should be performed by qualified personnel
Installation Disclaimer:
Incorrect installation, wiring, or application outside recommended conditions may result in inaccurate readings or sensor damage. Suitability for the intended application must be independently verified prior to installation.