Sensor & Measurement
-
Sensor Type: K-type thermocouple
-
Measurement Principle: Thermoelectric temperature sensing
-
Measurement Range: 120 °C and above (installation and construction dependent)
-
Measurement Type: Temperature
Measurement Disclaimer:
The stated temperature range applies to the thermocouple junction only. Maximum continuous operating temperature depends on probe construction, sheath material, cable insulation, and installation conditions. Continuous operation near upper limits may reduce sensor lifespan.
Electrical Specifications
Electrical Disclaimer:
Measurement accuracy depends on correct cold-junction compensation, compatible instrumentation, and correct polarity. Incorrect wiring or incompatible instruments may result in inaccurate readings.
Mechanical Specifications
-
Probe Material: Stainless steel
-
Probe Style: Standing probe
-
Electronics: None (passive sensor)
Mechanical Disclaimer:
Mechanical durability depends on installation method, vibration levels, and exposure to thermal cycling. Excessive mechanical stress or bending may damage the sensing junction.
Environmental & Protection
Environmental Disclaimer:
Environmental resistance applies to the probe body only. Cable insulation and termination points may require additional protection depending on ambient temperature, moisture, or chemical exposure.
Compliance & Safety
-
Certification: CE marked (manufacturer declaration)
-
Hazardous Substances: No high-concern chemicals declared
-
Country of Origin: Mainland China
-
Intended Use: Industrial temperature measurement
Compliance Disclaimer:
CE marking applies to the sensor as a component only. Final system compliance—including electrical safety, EMC, and installation standards—is the responsibility of the system designer or installer. ProSense does not certify complete systems or site installations.
Installation & Use Limitations
-
Passive temperature sensor only
-
Not safety-rated
-
Not suitable as a primary over-temperature protection device
-
Installation should be performed by qualified personnel
Installation Disclaimer:
Incorrect installation, wiring, or use outside recommended conditions may result in inaccurate readings or sensor damage. Suitability for the intended application must be independently verified prior to installation.