Electromagnetic Flow Meter – Non-Intrusive, Accurate & Corrosion-Resistant
Versatile electromagnetic flow meter for accurate, obstruction-free measurement of liquids with solids or corrosive media. Ideal for water treatment, chemical, pulp, food, and pharmaceutical industries.
Product Description
This electromagnetic flow meter is engineered for precise and maintenance-free fluid measurement across a wide range of applications—from large-scale water supply systems to hygienic pharmaceutical production. Its smooth, straight-through measuring tube allows for the accurate monitoring of liquids mixed with solids, such as slurry, sewage, pulp, or mud, without the risk of clogging or pressure drop.
With no moving parts and no flow obstruction, it provides highly reliable measurements with minimal maintenance. The unit is unaffected by variations in fluid properties such as density, viscosity, temperature, or pressure, making it ideal for challenging environments across multiple industries—including steel, chemical processing, pulp and paper, mining, and food and beverage.
Available in a wide range of sizes, including small-diameter models for cleanroom and sanitary settings, this flow meter offers long-term durability, energy efficiency, and accurate performance in both aggressive and high-demand environments.
Key Features:
-
Obstruction-free, self-cleaning flow path suitable for fluid-solid mixtures
-
No pressure loss during flow measurement—maximizing energy efficiency
-
Accurate volume flow unaffected by fluid density, temperature, or pressure
-
Handles highly corrosive and abrasive media with ease
-
Wide diameter range for everything from industrial pipelines to sanitary applications
-
Ideal for industries including wastewater treatment, steel, chemicals, pulp & paper, pharmaceuticals, and food processing
-
Specifications
Maximum velocity of flow 15m/s Accuracy DN15 ~ DN600 ±0.5% of the indicated value (flow velocity ≥ 1m/s), ±0.2%** +3mm/s (flow velocity < 1m/s) DN700 ~ DN3000 ±0.5% of the indicated value (flow velocity ≥ 0.8m/s) ±4mm/s (flow velocity < 0.8m/s) Fluid Electrical Conductivity ≥50μS/cm Nominal pressure DN10 ~ DN200 1.6MPa DN250 ~ DN1000 1.0MPa DN1200 ~ DN2000 0.6MPa DN2200 ~ DN3000 0.6MPa Ambient temperature Sensor -25°C~ +60°C Converter & Integrated type -10°C~ +60°C Lining material &
Fluid maximum temperature
Lining material Separate type Integrated type PTFE (Polytetrafluoroethylene) 120°C (special customization) 70°C PFA (Perfluoroalkoxy resin) 180°C (special customization) 70°C FEP (Fluorinated ethylene propylene) 160°C (special customization) 70°C Polychloroprene Rubber 80°C (special customization) 70°C PUR (Polyurethane) 80°C 70°C Signal electrode form Fixed type ( DN15 ~ DN2600 )、scraper type ( DN80 ~ DN3000 ) Signal Electrode &
Ground Electrode Materials
Molybdenum-containing stainless steel, Hastelloy B, Hastelloy C, Titanium,
Tantalum, latinumiridium alloy, stainless steel coated tungsten carbide
Connection flange material Carbon steel Grounding flange material Stainless steel 1Cr18Ni9Ti Inlet protection flange material DN15 ~ DN600 Stainless steel 1Cr18Ni9Ti DN700 ~ DN3000 Carbon steel IP Rate DN15 ~ DN150separable rubber or polyurethane lined sensor IP65, IP68 (special customization) DN200 ~ DN2600separable rubber or polyurethane lined sensor IP68, 10 meters underwater Other sensors and all converters IP65 Spacing (separate type) The distance between the converter and the sensor is generally not more than 100m; if it exceeds 100m, special customization is required. *DN700 ~ DN3000, the accuracy of special order can reach +0.3% of the indicated value (flow velocity ≥ 1m/s) or +3mm (flow velocity < 1m/s).
*Specially provide 0.2% accuracy flow meter.
Lining material Main performance Applications PTFE(Polytetrafluoroethylene) 1. It is the material that has most stable chemical property among plastics:
resistant to boiling hydrochloric acid, sulfuric acid, nitric acid and aqua regia, also resistant to concentrated alkali and various organic solvents, not resistant to
corrosion by chlorine trifluoride, high temperature oxygen trifluoride, high flow
rate liquid fluorine, liquid oxygen and ozone.
2. Poor wear resistance.
3. The ability to resist negative pressure is poor.
1. 100°C, 150°C (special customization)
2. Strong corrosive media such as concentrated acid
and alkali.
3. Hygienic media.
PCR(Polychloroprene Rubber) 1. It has excellent elasticity, high breaking force and good wear resistance.
2. It is resistant to the corrosion of general low-concentration acid and alkali salt media, and not resistant to the corrosion of oxidative media.
1. 80°C, 120*C (special customization)
2. General water, sewage, weak abrasive mud, ore pulp.
PUR (Polyurethane) 1. Excellent wear resistance (equivalent to ten times that of natural rubber). 2. Acid and alkali resistance is poor.
3. It cannot be used for water mixed with organic solvents.
1. < 80°C
2. Neutral and strong abrasive slurry, coal slurry, mud, etc
Product Manual